Thermo Scientific Gallery Discrete Analyzer, Type 861, with Racks
Automated discrete photometric analyzer, Type 861 without the ECM module, factory set up for food testing and running on 100-240 Vac, sold with sample and reagent racks and its installation binder; the workstation PC and Gallery software are not included.
Paying by PO? We'll send a formal quote first.
Alaska, Hawaii or international delivery? Request a freight quote.
At a Glance

Photometers
Thermo Scientific Gallery Discrete Analyzer, Type 861, with Racks
Automated discrete photometric analyzer, Type 861 without the ECM module, factory set up for food testing and running on 100-240 Vac, sold with sample and reagent racks and its installation binder; the workstation PC and Gallery software are not included.
| QC PASS |
Tested & Working
Lightly Used, Excellent
|
At a glance
What's Included
- ✓Thermo Scientific Gallery discrete analyzer, Type 861
- ✓Sample rack carousel segments and reagent racks, as pictured
- ✓Gallery Installation Binder with Quality Assurance Certificate
- ✓USB memory stick for analyzer data backup, in the binder
- ✓Windows 10 workstation image USB stick (service use), in the binder
- ✓Hazard label sheet, in the binder
- ✓USB key labeled with the analyzer serial number, in the pouch inside the cover
- ✓Power cord
- ✓Nothing else is included unless shown in the photos
Condition & Testing
Specifications
| Absorbance range | 0 to 3.5 A |
|---|---|
| Barcode reading | Code 128, USS Codabar, Interleaved 2 of 5 and Code 39 with check digit |
| Cuvettes | Disposable DECACELL cuvettes; 36 cuvettes with 10 reaction cells, 360 measurement cells |
| Dimensions (W x D x H) | 75 x 70 x 62 cm; 130 cm high with cover open |
| Dispensing precision | CV 2% or less for volumes of 2 µL and over |
| Filters | 12 filter positions, 340 to 880 nm |
| Incubation temperature | 25 to 60 °C, no cooling, preset to 37 °C |
| Light source | Xenon flash lamp |
| LIS interface | CLSI LIS02-A2 over RS-232 or TCP/IP |
| Noise | Under 60 dB(A) at 1 m |
| Operating environment | 18 to 30 °C, 40 to 80% RH non-condensing |
| Photometer | Single-channel interference filter photometer with beam-splitting reference |
| Power | 100-240 Vac, 50-60 Hz, 250 W |
| Reaction volume | 120 to 300 µL |
| Reagent vials | 10 mL and 20 mL |
| Reagent volume | 2 to 240 µL |
| Reproducibility | SD under 0.005 A at 2 A |
| Resolution | 0.001 A |
| Sample and reagent racks | 9- or 18-position sample racks and 6-position reagent racks, up to 6 racks in the cooled disk |
| Sample containers | 0.5, 2.0 and 4.0 mL cups and sample tubes (12 to 16 mm diameter, 75 to 100 mm long) |
| Sample volume | 2 to 120 µL, extendable to 240 µL |
| Throughput | Up to 200 tests/hour with a one-reagent method |
| Use restriction | Research use only, not for use in diagnostic procedures |
| Water consumption | 1.5 L/hour deionized water |
| Weight | 85 kg |
Specs from manufacturer literature for reference. Verify against your application.
Terms & Conditions
Payment
- We accept most payment types and work with your organization's accounting requirements.
- Need a formal quote or want to pay by PO? Contact us before you order.
Shipping
- Items ship within 1 to 2 business days after cleared payment.
- We ship by USPS, FedEx, UPS, or freight to all 50 states and internationally.
- International buyers pay customs and import duties.
- Need expedited service or billing to your own FedEx or UPS account? Tell us at purchase.
- You may arrange your own shipping through your own carrier on request.
Return Policy
- 60-day returns from the date of delivery, unless stated otherwise.
- If something isn't right, contact us first so we can fix it.
Why BioLabTek
- ✓We power on and function-test every unit and note all findings
- ✓Photos show the exact unit you receive
- ✓Instruments packed to survive the carrier
- ✓POs and formal quotes welcome for academic and corporate buyers