Thermo Scientific Gallery Discrete Analyzer, Type 861
Automated discrete photometric analyzer, Type 861 without the ECM module, factory set up for food testing and running on 100-240 Vac; two units available, and the workstation PC and Gallery software are not included.
Paying by PO? We'll send a formal quote first.
Alaska, Hawaii or international delivery? Request a freight quote.
At a Glance

Photometers
Thermo Scientific Gallery Discrete Analyzer, Type 861
Automated discrete photometric analyzer, Type 861 without the ECM module, factory set up for food testing and running on 100-240 Vac; two units available, and the workstation PC and Gallery software are not included.
| QC PASS |
Tested & Working
Lightly Used, Excellent
|
At a glance
What's Included
- ✓Thermo Scientific Gallery discrete analyzer, Type 861
- ✓USB A to B interface cable
- ✓USB key labeled with the analyzer serial number, in the pouch inside the cover
- ✓Nothing else is included unless shown in the photos
Condition & Testing
Specifications
| Absorbance range | 0 to 3.5 A |
|---|---|
| Barcode reading | Code 128, USS Codabar, Interleaved 2 of 5 and Code 39 with check digit |
| Cuvettes | Disposable DECACELL cuvettes; 36 cuvettes with 10 reaction cells, 360 measurement cells |
| Dimensions (W x D x H) | 75 x 70 x 62 cm; 130 cm high with cover open |
| Dispensing precision | CV 2% or less for volumes of 2 µL and over |
| Filters | 12 filter positions, 340 to 880 nm |
| Incubation temperature | 25 to 60 °C, no cooling, preset to 37 °C |
| Light source | Xenon flash lamp |
| LIS interface | CLSI LIS02-A2 over RS-232 or TCP/IP |
| Noise | Under 60 dB(A) at 1 m |
| Operating environment | 18 to 30 °C, 40 to 80% RH non-condensing |
| Photometer | Single-channel interference filter photometer with beam-splitting reference |
| Power | 100-240 Vac, 50-60 Hz, 250 W |
| Reaction volume | 120 to 300 µL |
| Reagent vials | 10 mL and 20 mL |
| Reagent volume | 2 to 240 µL |
| Reproducibility | SD under 0.005 A at 2 A |
| Resolution | 0.001 A |
| Sample and reagent racks | 9- or 18-position sample racks and 6-position reagent racks, up to 6 racks in the cooled disk |
| Sample containers | 0.5, 2.0 and 4.0 mL cups and sample tubes (12 to 16 mm diameter, 75 to 100 mm long) |
| Sample volume | 2 to 120 µL, extendable to 240 µL |
| Throughput | Up to 200 tests/hour with a one-reagent method |
| Use restriction | Research use only, not for use in diagnostic procedures |
| Water consumption | 1.5 L/hour deionized water |
| Weight | 85 kg |
Specs from manufacturer literature for reference. Verify against your application.
Terms & Conditions
Payment
- We accept most payment types and work with your organization's accounting requirements.
- Need a formal quote or want to pay by PO? Contact us before you order.
Shipping
- Items ship within 1 to 2 business days after cleared payment.
- We ship by USPS, FedEx, UPS, or freight to all 50 states and internationally.
- International buyers pay customs and import duties.
- Need expedited service or billing to your own FedEx or UPS account? Tell us at purchase.
- You may arrange your own shipping through your own carrier on request.
Return Policy
- 60-day returns from the date of delivery, unless stated otherwise.
- If something isn't right, contact us first so we can fix it.
Why BioLabTek
- ✓We power on and function-test every unit and note all findings
- ✓Photos show the exact unit you receive
- ✓Instruments packed to survive the carrier
- ✓POs and formal quotes welcome for academic and corporate buyers